Open the project folder on GitHub · Schematic PDF
The op-amp model with no feedback, showing its own frequency response: 86 dB of gain, a pole at 20 Hz, and unity gain at 400 kHz.
Circuit
U1 runs from ±15 V. V3, with an AC value of 1, drives the non-inverting input. The inverting input is grounded, and the output drives R1 = 1 MΩ. U1 uses kicad_builtin_opamp.lib with its offset set to zero, VOFF=0 in U1’s Simulation Model parameters (see below). The AC sweep runs from 1 Hz to 10 MHz.
What To Look For
- The model’s parameters are GAIN = 20,000 and POLE = 20 Hz. The gain is 20,000 (86 dB) at low frequency and 3 dB down at 20 Hz.
- Above the pole it falls 20 dB per decade, so gain × frequency stays at 20,000 × 20 Hz = 400 kHz: a gain of 400 at 1 kHz, and 1 at 400 kHz. That product is the gain-bandwidth that sets every closed-loop example’s bandwidth.
- Why
VOFF=0: the model normally adds a 10 mV input offset, as real op-amps have. With no feedback, 10 mV × 20,000 = 200 V would drive the output into the +15 V rail, and the AC sweep would show a saturated amplifier instead of this curve.
The simulation gives 19,967 at 1 Hz, the pole at 20.0 Hz, and unity gain at 400 kHz.
How To Run
Open OPamp-open-loop.kicad_sch in KiCad, click Simulate, and run the AC tab. It plots the gain of V(Out).
Try This
- Delete
VOFF=0from U1’s parameters and rerun: the gain collapses to about 0.026, because the output is pinned at a rail. - Change POLE or GAIN in U1’s parameters and watch the gain-bandwidth move. Then rerun OPamp Noninverting with the same values.
Simulated Results
Generated by ngspice from the analyses in this example’s workbook.
Made for KiCad 10.