LC resonance and Q, an RLC circuit’s step response, and coupled inductors as transformers.
LC Series Resonance
A series LC circuit passes everything at its resonant frequency, 159 kHz, where the inductor and capacitor cancel. With a Q of 0.1, the peak is very broad.
LC Parallel Resonance
A parallel LC tank blocks its resonant frequency, 159 kHz, making a sharp notch with a Q of 10.
RLC Step Response
A 1 V step into two series RLC circuits: with ζ = 0.158 the capacitor voltage overshoots to 1.605 V and rings at 4970 Hz, and with ζ = 1 it rises to 1 V without overshoot.
Transformer 1P 1S
Two coupled inductors as an ideal transformer, stepping 325 V peak (230 V RMS) down to 32.5 V with a 10:1 ratio.
Transformer 1P 2S
A transformer with one primary and two secondaries, each giving 32.5 V, one of them inverted.